In the calculation of the fixed tube sheet, the axial stress of the shell, the axial stress of the heat exchange tube, and the pull-off force q between the heat exchange tube and the tube sheet are calculated according to various working conditions with temperature difference. When the strength (or stability) conditions are met, expansion joints are required. In the calculation of the strength of the fixed tube sheet, when the thickness of the tube sheet is determined and no expansion joints are provided, sometimes the strength of the tube sheet is not enough. After the expansion joints are provided, the thickness of the tube sheet may meet the requirements. At this time, expansion joints can also be set to reduce the thickness of the tube sheet, but it should be determined from a comprehensive evaluation of material consumption, manufacturing difficulty, safety and economic effects.
U-shaped expansion joints are commonly used in fixed tube sheet heat exchangers, which have the advantages of compact and simple structure, good compensation and low price.
With the large-scale chemical equipment and power stations, the diameter of the tube sheet is also becoming larger and larger, and the tube sheet with a diameter of 4m-5m is very common. Large-scale tube sheets are characterized by a large number of tube holes, dense, small aperture, deep, and high requirements for precision and finish.